![]() P/n A29 PDA extension (in case Nexera includes a PDA detector)Ĭonfiguration for Clarity with one Nexis GC and one Nexera HPLC: P/n A24-001 LC Shimadzu license for one HPLC, 2x P/n A26 AS control (in case there is a Clarity controlled autosampler)Ĭonfiguration for Clarity with two Nexera HPLCs: P/n A23-001 GC Shimadzu license for one GC ![]() P/n C50-28 Clarity Shimadzu Edition for 1 Instrument It requires a Shimadzu license for each connected instrument p/n A23-001 for GC-2030 and A24-001 for Nexera HPLC Series.Ĭlarity - Shimadzu Edition is available only in Europe.Ĭonfiguration for Clarity Shimadzu Edition with one Nexis GC: The control of Shimadzu Nexis GC-2030 GC and Nexera LC-40 HPLC is available in Clarity - Shimadzu Edition (p/n C50-28). Update Clarity to the newest version (in Clarity 8.7 memory handling is improved).Do not open resulting chromatograms when Sequence is running (Disable the checkbox in the Open column).Do not use "Open chromatograms in Overlay" when running the Sequence.This will save your method without previous versions, decreasing the file size. Try to save the method using the command Save As under a new name.These versions increase Method file size when such a method is used, memory can be depleted, forcing the software to misbehave. Since version 8.3, every saving of such method results in creating another method's version (number of versions is displayed at the top of Method setup behind the method name as "- #number"). This may be caused by using a particular method, which has been saved over and over again due to some modifications. Sometimes you may get the error "Out Of Memory", caused, e.g., when opening a chromatogram in the Chromatogram window. To display the marks, Show Events in Graph Properties in Acquisition and Chromatogram windows must be enabled (Dialog can be invoked by right-clicking the graph area in the respective window and clicking Properties.).Ĭlarity is a 32-bit process, which means it can use the max of 2GB RAM, but if you use more than one demanding instrument, it can still be beneficial to have 8 GB RAM, so the PC has enough RAM left for OS and other apps.Input field determines which digital input records the event.Source field determines which module provides the digital input.Name field determines the label of the event.Event Table tab - set according to the image, where:.Measurement tab - External Start/Stop enabled and set to Start Only.HW with digital input or Virtual Digital Input Output Loop module configured to Instrument.The digital input can be triggered by pressing the start button when it is provided by HW, or by pressing the corresponding Digital Output in the Device monitor when provided by the Virtual Digital Input Output Loop module. With proper settings, triggering the digital input is recorded as an event (vertical line labeled with name and RT) in the Acquisition and Chromatogram windows. ![]() Colibrick A/D converter) or the Virtual Digital Input Output Loop module and Event Table tab from the Method Setup dialog. Mark in a chromatogram can be created utilizing any HW with digital input (e.g.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |